A portable diesel generator for sale is a practical power solution for construction projects, factories, commercial facilities and other applications that require independent electrical power.
The available generator range covers 30kw to 400kw, with a rated voltage of 400/230V, frequency of 50Hz and rated speed of 1500rpm. The generator uses a three-phase, four-wire electrical system.
The system combines a diesel engine, generator and control system into an integrated power unit. Different power configurations can be selected according to the required electrical load and application.
Portable Diesel Generator for Sale: Technical Specifications
The main technical parameters are:
| Power | 30kw | 100kw | 150kw | 200kw | 300kw | 400kw |
| cylinders | 4 cylinder | 6 cylinder | 6 cylinder | 6 cylinder | 6 cylinder | 6 cylinder |
| voltage | 400/230V | 400/230V | 400/230V | 400/230V | 400/230V | 400/230V |
| Frequency Range | 50HZ | 50HZ | 50HZ | 50HZ | 50HZ | 50HZ |
| Rotating speed | 1500rpm | 1500rpm | 1500rpm | 1500rpm | 1500rpm | 1500rpm |
| Cylinder diameter *stroke (mm) | 100*115 | 105*125 | 105*130 | 126*130 | 126*155 | 135*160 |
| Rated current | 54A | 180A | 270A | 360A | 540A | 720A |
| Phase | Three-phase four-wire | Three-phase four-wire | Three-phase four-wire | Three-phase four-wire | Three-phase four-wire | Three-phase four-wire |
Choosing a generator starts with the required output power. The available range provides several configurations for different operating requirements.
The generator models cover output requirements from 30kW to 400kW, allowing buyers to select a configuration based on the electrical demand of the project.
For projects with different load requirements, selecting the appropriate rated power is the first step before confirming the complete generator configuration.


Receive Detailed Parameter List
Industrial Generator Set: Key System Advantages
The portable diesel generator for sale integrates the main power-generation components into one system. Its configuration can be understood through three core elements.
Diesel Engine: Primary Power Source
The diesel engine provides the mechanical power required for electricity generation. The available configurations use different engine models according to generator output. For example, the 30kW unit uses the YG4D engine, while higher-output models use corresponding diesel engine configurations.
Advantage: Different engine configurations correspond to different generator power levels.
Benefit: Buyers can match the engine and generator configuration to the required output range.
Generator: Electrical Power Conversion
The diesel engine drives the generator to produce electrical power. The documented configurations use generator models matched with the corresponding engine and rated output.
Advantage: The engine and generator are configured as a matched power system.
Benefit: The complete unit provides a direct power-generation solution instead of requiring separate primary power and generation equipment.


Control System: Centralized Operation
The generator system includes a control system for operating and monitoring the generating unit. The documented configuration includes a control system as part of the complete generator package.
Advantage: The main generator functions are integrated into one control system.
Benefit: Operators can manage the generating equipment as a complete power unit.
Find The Right Solution For Your Job
Portable Generator for Construction Site Applications
A portable diesel generator for sale use can provide independent power where a stable grid connection is unavailable or where temporary project power is required.
1. Construction Projects
Construction sites may require electrical power for equipment, tools and temporary site facilities. The 30-400kW power range provides multiple configurations for different project loads.
2. Industrial Facilities
Factories and industrial facilities can select generator configurations according to their required output. The available models extend from 30kW to 400kW, covering a broad range of documented power configurations.


3. Commercial and Public Facilities
The generator system can also be configured for facilities requiring independent electrical power. The three-phase, four-wire configuration is suitable for the documented 400/230V electrical system.
4. Backup and Independent Power Applications
Where independent generation is required, the generator combines the diesel engine, generator and control system into one complete unit. The configuration can therefore be selected according to the required rated output.
Get Your Project‑Specific Quote
Industrial Generator Set Configuration Guide
The complete system includes the major components required for diesel power generation. The documented structure includes the diesel engine, generator and control system.
For selection, buyers should first confirm:
- Required rated power.
- Required voltage.
- Operating frequency.
- Three-phase or other electrical requirements.
- Project application.
- Required generator configuration.
The available units use 400/230V, 50Hz, 1500rpm and three-phase, four-wire configuration as the documented standard specifications.
Find The Right Solution For Your Job
Industrial Genset FAQ
A: The documented generator range is 30kW to 400kW, with models including YG30GF, YG50GF, YG75GF, YG100GF, YG150GF, YG200GF, YG300GF and YG400GF.
A: The documented rated voltage is 400/230V and the frequency is 50Hz.
A: The documented rated speed is 1500rpm.
A: Yes. The documented electrical configuration is three-phase, four-wire.
A: The documented system includes the diesel engine, generator and control system, with different configurations matched to the rated power.
Get Your Project‑Specific Quote
Portable Diesel Generator for Sale for Your Power Project
With a 30-400kW output range and multiple matched engine-generator configurations, this diesel generator series provides flexible options for construction, industrial and independent power applications.
Contact us for generator specifications, model selection and configuration details based on your project power requirements.